Wiring diagram, Electrical installation 2 - 20 – Yaskawa E7B Drive Bypass User Manual

Page 58

Advertising
background image

Electrical Installation 2 - 20

Wiring Diagram

(1)

(2)

(3)

(4)

(5)

(6)

(T2)

(L2)

(T1)

(L1)

(T3)

(L3)

(1)

(2)

(1)

(2)

(1)

(2)

(T2)

(L2)

(T1)

(L1)

(T3)

(L3)

C2

C1

B2

A2

B1

A1

(2)

(4)

(6)

(1)

(3)

(5)

(95)

(96)

(T2)

(L2)

(T1)

(L1)

(T3)

(L3)

(T2)

(L2)

(T1)

(L1)

(T3)

(L3)

(2)

(4)

(6)

(1)

(3)

(5)

(95)

(96)

(T2)

(L2)

(T3)

(L3)

(T1)

(L1)

(2)

(4)

(6)

(1)

(3)

(5)

(1)

(2)

(1)

(2)

(1)

(2)

(95)

(96)

(95)

(96)

(2)

(4)

(6)

(1)

(3)

(5)

(1)

(2)

(1)

(2)

(1)

(2)

L1/A1

L1/A2

L2/B1

L2/B2

L3/C1

L3/C2

GND1

GND2

C2

C1

B2

A2

B1

A1

EG

+1

+2

MB

MC

MA

M1

M2

M3

M4

S1

S3

SC

S4

S5

SN

L1

L2

L3

T1

T2

T3

SP

A1

+V

AC

AC

E

A2

AC

+V

AC

+V

A2

FROM

CUSTOMER'S

A.C. LINES

L1

L3

L2

A.C. MOTOR #1

A.C. MOTOR #2

SHIELD

0R

0R

JUMPER

A.C. MOTOR #2

A.C. MOTOR #1

111

S10

SEE

NOTE 1

SEE

NOTE 1

EARTH

GROUND

LOAD

LINE

+

-

A2

ISOLATED

AUTO MODE

SPEED

REFERENCE

+V

TO A2

T3

T2

T1

T3

T2

T1

T3

T2

T1

T1

T2

T3

T1

T2

T3

SEE

NOTE 2

SEE

NOTE 2

SEE

NOTE 2

SEE

NOTE 2

TO A2

TO A2

TO A2

SEE

NOTE 5

1T1

1T3

1T2

5T1

5T3

5T2

4T2

4T1

4T3

1T2

1T1

1T3

1T2

1T1

1T3

1T3

1T1

1T2

4T3

4T2

4T1

3T1

3T2

3T3

2T1

2T2

2T3

L2

L1

+2

+1

L3

A2

AC

AC

DRIVE

INPUT

FUSES

INPUT

RFI

FILTER

OPTION F

OPTION E

DC BUS

CHOKE

MANUAL

SPEED POT

OPTION S

2 MOTOR

"AND"

OPTION A

OPTION K

STD. AUTO MODE SPEED REFERENCE

STD.

4-20MADC

0-10VDC

MA

111

MA

3-15 PSI PRESSURE TRANSDUCER

OPTION P

5% LOAD

REACTOR

(SEE

TABLE 2)

OPTION N

L1

L2

L3

OPTION R
3% INPUT

REACTOR

TO DRIVE

TERMINAL

E

LEAD WIRE

OPTION N

GREEN

(GRN) (YEL)

(YEL)

(YEL)

DELTA-WYE

CAPACITIVE

INPUT FILTER

A5

GND LUG

OR

OPTION Z

OPTION X

(SEE

TABLE 3

FOR CB1

AMPERE

RATINGS)

PE

E

F10

F12

F11

A.C. MOTOR

(T1) (T3)

(T2)

(T1)

(T2)

(T3)

(T2)

(T1) (T3)

(T1) (T3)

(T2)

(T1) (T3)

(T2)

E

OFF

OFF

ON

ON

1

2

DIP SWITCH S1

TERMINAL

BOARD

DRIVE

FAULT

DRIVE

RUNNING

JUMPER

SERIAL

COMM. RUN

REMOVE JUMPER

FOR

DC BUS CHOKE

OPTIONS X OR Z

SEE THE

APPROPRIATE

TECHNICAL

MANUAL FOR

NETWORK

CONNECTIONS

OPTION L

CN2

CN1

CN2

CONTROL

BOARD

A6

TO CABINET

DOOR MOUNTED

DRIVE KEYPAD

WITHOUT

OPTION P

WITH OPTION P

WITH

OPTION S

RUN

FWD

BYPASS DRIVE

ENABLE

SEQ. COM.

FAULT RESET

HAND/AUTO

COM.

(R)

(S)

(T)

E7

DRIVE

(U)

(V)

(W)

+24V

MANUAL REF. IN

0-10VDC

(20K OHM)

+15VDC

20mA MAX.

ANALOG

COM.

ANALOG
COM.

(G) TB3
SHIELD

AUTO REF. IN

(AS SET

BY H3-08)

COM.

VCC

J2

3-14.5 PSI

PNEUMATIC

SIGNAL

3-15 PSI

FOLLOWER

PART NO.

UTC000038

4-20MA

OUTPUT

CB1

K1

F3

F4

F5

K2

L4

S10

K4

K5

K3

S12

S11

F9

F8

F7

EG

CG1

L2

PG1

L2/1.07

L11/1.23

L12/1.22

L3/1.14

L4/1.15

L5/1.16

L6/1.17

L7/1.18

L8/1.20

L9/1.21

L1/1.04

L1/1.04

L1

L13/1.24

A1

A4

L14/1.21

L15/1.20

L15/1.32

L14/1.31

2L1

2L2

2L3

1L3

1L3

1L1

1L2

111

1T1

1T2

1T3

MC

M4

M3

M2

MA

1L1

1L2

MA

MA

S1

S1

2T1

2T2

2T3

(W)

(B)

SN

S5

(R)

(R)

(B)

2 MOTOR

"OR"

OPTION D

Advertising