downstream data path. The convention is “from port to FIFO.” Thus selecting a port “from”
which a frame is received displays the FIFOs to which the frame may be classified.
Classification will be discussed in the next section. Selecting any FIFO terminating at a
particular port or logical link has the effect of also selecting the related entity. In the
example above link 1 has been selected.

Notice that downstream FIFOs are labeled relative to their associated link. For downstream
FIFOs the GUI uses the naming convention Link.FIFO. Therefore the “full name” of the
selected FIFO is 1.1.

Upstream the GUI will use the convention Port.FIFO. In the example above the full FIFO
name is 1.2, indicating that the FIFO is #2 of User Port 1.

„

Provisioning Number of Logical Links to Register

Up to 3 Links may be registered per ONU. The number of Logical Links is determined by
the Num LLID control. This control is only visible when one of the User Ports is selected.