ProSoft Technology PS69-DPM User Manual

Page 60

Advertising
background image

Contents

PS69-DPM ♦ CompactLogix or MicroLogix Platform

User Manual

PROFIBUS DPV1 Master

Page 60 of 130

ProSoft Technology, Inc.

October 1, 2014

Offset

Register Type

Name

40 to 55

Global State Field

Sl_state[128]

56 to 71

Global State Field

Sl_diag[128]

72

Slave Diagnostic Field

Slave Address

73

Slave Diagnostic Field

Slave Diag Failure

74

Slave Diagnostic Field

Station Status_1

75

Slave Diagnostic Field

Station Status_2

76

Slave Diagnostic Field

Station Status_3

77

Slave Diagnostic Field

Master Address

78 to 79

Slave Diagnostic Field

Ident Number

80

DPV1 Alarm Indication

Alarm_Status

81

DPV1 Alarm Indication

Rem_Add

82

DPV1 Alarm Indication

Alarm_Cnt

83

DPV1 Alarm Indication

Slot_Number

84

DPV1 Alarm Indication

Seq_Nr

85

DPV1 Alarm Indication

Alarm_Type

86

DPV1 Alarm Indication

Alarm_Spec

87

DPV1 Alarm Indication

Reserved

88 to 495

PROFIBUS Input Area

Inputs (408 Bytes)

Output Array

Below is a summary of the register layout of the output area of the PROFIBUS Master
module. The offset values are defined as byte.

Offset

Register Type

Name

0

Device Command Register

Command Bits

1

Device Command Register

Handshake Request Bits

2

Device Command Register

Reserved

3

Device Command Register

Reserved

4

Slave Diag

Slave Address

5

Slave Diag

Function

6

Slave Diag

Reserved

7

Slave Diag

Reserved

8

Global Control Command

Slave_ Address

9

Global Control Command

Control _Command

10

Global Control Command

Group_Select

11

Global Control Command

Reserved

12

Reserved Register

Reserved

13

Reserved Register

Reserved

14

Reserved Register

Reserved

15

Reserved Register

Reserved

16 to 495

PROFIBUS Output area

Outputs (480 Bytes)

Advertising