Settings for connecting with the remote cameras – Panasonic AW-RP60 Remote Camera Controller User Manual

Page 33

Advertising
background image

33

3.

Set [EXEC] (F4 dial) to [SETTING], then press the F4

dial.

“Auto IP setting” starts.

The “AUTO IP SETTING” message is displayed while “auto IP

setting” is being performed.

z

The “COMPLETE” message is displayed when the entire process

is successful.

The remote cameras are automatically rebooted, and they restart

with the new IP addresses which were set.

The remote cameras can now be operated from the unit.

z

The “SET UP ERR” message is displayed when IP address setting

fails.

The cause of the problem is likely to be a network malfunction.

Check the connection status of the hub and LAN cables, and then

retry the “auto IP setting” operation.

„

„

Leaving the IP addresses of the additional devices to

be introduced unchanged and automatically updating

the connection destination IP addresses set on the

unit

<Overview of operation>

By executing [KEEP] in the [AUTO SET] item of the [AUTO IP SET]

SYSTEM menu, links are set.

With [KEEP], the unit first searches within the same subnet.

Then, links are set between the newly detected remote cameras and

camera numbers for which the connection type is set to [NON] on the

unit.

At that time, the IP addresses of the remote cameras are kept as is

and the connection destination IP address values set on the unit are

overwritten.

Example:

(1) Operation is being performed with the three remote cameras A, B

and C set to CAM1, CAM2 and CAM3, respectively.

(2) The new remote camera D (with the following IP address value) is

added.

Remote camera D :

192.168.0.20

(3) Connection types set on the unit ([SYSTEM] > [CONNECT

SETTING])

CAM1 :

LAN

CAM2 :

LAN

CAM3 :

LAN

CAM4 :

NON

(4) Connection destination IP address set on the unit ([SYSTEM] >

[MANUAL IP SET/USER AUTH])

CAM4 :

192.168.0.13

When [KEEP] is executed in this state, the IP address of remote

camera D is not changed, the connection destination IP address set

on the unit is overwritten with the following value, and a link is set to

remote camera D.

Connection destination IP address of CAM4:

192.168.0.20

192.168.0.13

192.168.0.20

192.168.0.20

Remote

camera A

Remote

camera B

Remote

camera C

CAM4

Remote

camera D

Connection destination IP

address of CAM4

z

z

If camera numbers for which the connection type is set to other than

[Serial] include a camera number for which the connection destination

IP address is set to the same value as the IP address of a detected

remote camera, the connection destination IP address set on the unit

is not updated. The connection destination IP address is kept as is

and a link is set for the corresponding camera number and remote

camera.

z

z

Set the subnet mask of the unit and remote camera to the same

value. If the subnet masks are different, no operations using the

network will be possible.

Note

Settings for connecting with the remote cameras

(continued)

Advertising