<Operating procedure>

1.

Connect the additional remote cameras to be introduced

and the unit to the network within the same subnet.

2.

Select the [AUTO IP SET] SYSTEM menu, turn the F1

dial to display [KEEP], then press the F1 dial.

AUTO IP SET 1/1

AUTO SET

KEEP

NO?

TOTAL

EXEC

NEW

AW-UE70

The number of devices currently being managed by the unit (All

remote cameras and the newly detected number of devices are

displayed in [NEW] and [TOTAL].)

NEW

:

Newly detected cameras

TOTAL :

The number of all devices currently being managed by

the unit + Number of newly detected devices

3.

Set [EXEC] (F4 dial) to [SETTING], then press the F4

dial.

“Auto IP setting” starts.

The “AUTO IP SETTING” message is displayed while “auto IP

setting” is being performed.

z

The “COMPLETE” message is displayed when the entire process

is successful.

The remote cameras can now be operated from the unit.

z

The “IP Duplicate!” message is displayed when the IP address of

an already running device and the IP address of a remote camera

being added are the same, and the link setting is not made.

Check the IP addresses of the additional remote cameras to be

introduced, and then perform the “auto IP setting” operation again.

z

The “SET UP ERR” message is displayed when IP address setting

fails.

The cause of the problem is likely to be a network malfunction.

Check the connection status of the hub and LAN cables, and then

retry the “auto IP setting” operation.

Connection device detection

z

z

When the number of new devices detected by [RENEW] or [KEEP]

exceeds the number of devices that can be registered (200 remote

cameras), “C/S OVER!” appears.

Auto IP setting can be executed even in this state, but IP addresses

will be set only for the number of devices that can be registered.

z

z

The unit may not be able to detect all of the remote cameras when,

for example, multiple remote cameras are started at the same time.

In this case, select [RETRY] in the [EXEC] item and press the F4 dial

to retry.

z

z

If the number of newly detected devices does not match the number

of devices that are to actually be set, such as if the power of the

remote camera was not on, etc., solve the problem, then select

[RETRY] in the [EXEC] item and press the F4 dial to retry.

z

z

When adding another remote camera controller (AW‑RP60 [this

unit]), set an IP address that is not a duplicate of any IP address

within the same network before making the connection.

z

z

Execute “auto IP setting” when devices not applicable for auto

IP setting (devices other than the remote cameras) are in a

non‑operation state in the same network. After executing “auto

IP setting”, connect these devices after checking that there is no

duplicate IP address within the same network.