Configuring line use, Setting channel groups, Configuring line use -2 – Lucent Technologies PortMaster User Manual

Page 170: Setting channel groups -2

Advertising
background image

Configuring General Settings

11-2

PortMaster Configuration Guide

Command> show Line0

Configuring Line Use

You can use a line as a single E1 or T1 line, as PRI B channels, as fractional E1 or T1
lines divided into channel groups, or for inband signaling for channelized T1.

Note – T1 and E1 lines require an external clock signal provided by the device to which
the PortMaster is connected, or by the telephone company network.

To configure a line, use the following command. Table 11-1 explains the line use
options.

Command> set Line0 isdn|t1|e1|fractional|isdn-fractional|inband

You use the fractional keyword in this command to break up a channelized T1 line
into groups. The isdn-fractional keyword refers to PRI only.

Setting Channel Groups

You can divide the channels of a T1 or E1 line into numbered groups after the line type
has been set to fractional with the set Line0 fractional command.

To set the channel group for a T1 or E1 line, use the following command. Table 11-1
explains the channel group options.

Command> set Line0 group Cgroup|none channels Channel-list

Table 11-1

Channel Group Options

Option

Description

Line0

Line0 or Line1.

Cgroup

Group number from 1 to 63, or none to unassign
channels.

Channel-list

Space separated list of one or more channel numbers, from
1 through 24 for T1, or 1 through 30 for E1. The channel
numbers do not have to be contiguous.