Configuring global settings, Configuring ethernet interface settings – Lucent Technologies PortMaster User Manual

Page 292

Advertising
background image

Configuration Steps for Leased Line Connections

19-6

PortMaster Configuration Guide

Configuring the PortMaster Office Router in Florence

Configure the settings for the PortMaster Office Router in Florence with the values in
the following sections.

Configuring Global Settings

Configure the global settings to the values shown in Table 19-4.

After you configure the global settings shown in Table 19-4, enter the following
command to save the configuration:

Command> save all

For more information about global settings, refer to Chapter 3, “Configuring Global
Settings
.”

Configuring Ethernet Interface Settings

Configure the Ethernet settings to the values shown in Table 19-5.

Table 19-4

Global Values

Setting

Command

IP gateway

set gateway 192.168.200.1

System name

set sysname office2

Table 19-5

Ethernet Values

Setting

Command

IP address

set ether0 address 192.168.1.1

Netmask

set ether0 netmask 255.255.255.0

IPX network

set ether0 ipxnet F1

IPX frame type

set ether0 ipxframe ethernet_802.2

Broadcast address

set ether0 broadcast high

RIP routing

set ether0 rip on

Advertising