Configuring dial-out port settings – Lucent Technologies PortMaster User Manual

Page 245

Advertising
background image

Using Office-to-Office Connections

15-9

Configuration Steps for an Office-to-Office Connection

Configuring Dial-Out Port Settings

For all ports on the PortMaster in Paris that you want enabled for dial-in and dial-out
(two-way service) to the Office Router in the London office, enter the values shown in
Table 15-7.

Leave all the other settings at their default values.

After you configure the port as shown in Table 15-7, enter the following commands to
reset the port and save the configuration:

Command> reset s1
Command> save all

For more information about asynchronous ports, refer to Chapter 5, “Configuring an
Asynchronous Port.

Table 15-7

Two-Way Port Values

Setting

Command

Port type

set s1 network twoway

Speed 1

set s1 speed 1 115200

Speed 2

set s1 speed 2 115200

Speed 3

set s1 speed 3 115200

Modem control

set s1 cd on

Hardware flow control

set s1 rts/cts on

Software flow control

set s1 xon/xoff/off

Idle timer

set s1 idle 5

Dial group

set s1 group 1

Advertising