Configuring settings for network and login users, Setting a password, Setting the idle timer – Lucent Technologies PortMaster User Manual

Page 118: Setting the session limit, Configuring network users, Setting the destination netmask

Advertising
background image

Configuring Settings for Network and Login Users

7-4

PortMaster Configuration Guide

Configuring Settings for Network and Login Users

The following settings can be configured for either network or login users.

Setting a Password

To set a password for either a login or network user, use the following command:

Command> set user Username password Password

The password can contain between 0 and 16 printable ASCII characters.

Setting the Idle Timer

The idle timer defines the number of minutes or seconds the line can be idle—in both
directions—before the PortMaster disconnects the user. You can set the idle time in
seconds or minutes, with any value between 2 and 240. The default setting is 0 minutes.
The idle timer is not reset by RIP, keepalive, or SAP packets.

To set the idle timer, use the following command:

Command> set user Username idle Number [minutes|seconds]

To disable the idle timer, set the time to 0 minutes.

Setting the Session Limit

You can define the maximum length of a session permitted before the PortMaster
disconnects the user. The session length can be set to between 0 and 240 minutes.

To set the session limit, use the following command:

Command> set user Username session-limit Minutes

To disable the session limit, set the time to 0.

Configuring Network Users

Network users establish PPP or SLIP connections with the network as soon as they have
been authenticated.