Troubleshooting a Leased Line Connection

If you still have problems, enter the following commands:

Command> set debug 0x51
Command> set console s1

Then set the CSU/DSU for local loopback. You should see the following message:

LCP_APPARENT_LOOP

For more information about the interpreting the results of the debug command,
refer to the PortMaster Troubleshooting Guide.

If the local loopback shows network connectivity in the local router, take the
CSU/DSU out of loopback and set line loopback on the remote CSU/DSU. If the
remote loopback test does not show network connectivity in the remote router, the
problem is either in the configuration of one of the CSU/DSUs or in the line itself.

When you finish, enter the following commands to turn off the debug utility:

Command> set debug off
Command> reset console

Contact your carrier to review your configuration and the status of their line.