Configuring the office router in london, Configuring the office router in london -4, Configuring global settings – Lucent Technologies PortMaster User Manual

Page 240: Configuring ethernet interface settings

Advertising
background image

Configuration Steps for an Office-to-Office Connection

15-4

PortMaster Configuration Guide

Configuring the Office Router in London

Configure the following settings on the PortMaster PCMCIA Office Router in the
London office to enable London office users to access the main office network in Paris
on demand.

Configuring Global Settings

Configure the global settings shown in Table 15-1. The values shown in the table only
apply to this example. When you are configuring your PortMaster, use values
appropriate for your network.

After you configure the global settings shown in Table 15-1, enter the following
command to save the configuration:

Command> save all

For more information about global settings, refer to Chapter 3, “Configuring Global
Settings
.”

Configuring Ethernet Interface Settings

Configure the Ethernet settings shown in Table 15-2.

Table 15-1

Global Values

Setting

Command

IP gateway

set gateway 192.168.1.1

System name

set sysname london

Table 15-2

Ethernet Values

Setting

Command

IPX network

set ether0 ipxnet F3

IPX frame type

set ether0 ipxframe ethernet_802.2

IP address

set ether0 address 192.168.200.1

Netmask

set ether0 netmask 255.255.255.0