Configuring global settings, Configuring ethernet interface settings – Lucent Technologies PortMaster User Manual

Page 226

Advertising
background image

Configuration Steps for a Synchronous V.25bis Connection

14-4

PortMaster Configuration Guide

Configuring Global Settings

Configure the global settings to the values shown in Table 14-1.

After you configure the global settings shown in Table 14-1, enter the following
command to save the configuration:

Command> save all

For more information about global settings, refer to Chapter 3, “Configuring Global
Settings
.”

Configuring Ethernet Interface Settings

Configure the Ethernet interface settings to the values shown in Table 14-2.

After you configure the Ethernet interface as shown in Table 14-2, enter the following
command to save the configuration:

Command> save all

Table 14-1

Global Values

Setting

Command

IP gateway

set gateway 192.168.1.1

System name

set sysname boston

Table 14-2

Ethernet Values

Setting

Command

IP address

set ether0 address 192.168.200.1

Netmask

set ether0 netmask 255.255.255.0

IPX network

set ether0 ipxnet F1

IPX frame type

set ether0 ipxframe ethernet_802.2

Broadcast address

set ether0 broadcast high

RIP routing

set ether0 rip on

Advertising