Troubleshooting the T1 Expansion Card

If the T1 expansion card is not properly installed, the show line2 command displays the
following status:

line2 not available

This message indicates that the card is either not present or installed incorrectly. If the
card is present, remove it, wait 5 seconds and reinstall it. Refer to your hardware
installation guide for instructions.

When you remove the card, the console displays the following message:

Card Service: Stopping wancard in slot 0

When you correctly reinstall the card, the console displays the following message:

Card Service: Starting wancard in slot 0
WANCTL version 0.0
WANCTL: sync_init - found device

Use the show alarms command to determine whether the T1 card is not operating (for
example, if the cable is pulled out). The PortMaster does not show an alarm if the card
is removed.

Command> show alarms

Command> show alarm 2851352

Alarm Id Age Severity Alarm Message
-------- ------ --------- ------------------
2851352 0 0 T1 line(2) down

---------------- Alarm Details -------------------------
Alarm Id: 2851352 Alarm Message: T1 line(2) down
Age in minutes: 0 Alarm repeated: 1 times
Severity: 0 Reported: SNMP