Serial port settings for a hardwired connection – Lucent Technologies PortMaster User Manual

Page 258

Advertising
background image

Configuration Steps for an Internet Connection

16-6

PortMaster Configuration Guide

Leave all other settings at their default values.

After configuring the serial port, enter the following commands to reset the port and
save the configuration:

Command> reset s1
Command> save all

For more information about asynchronous ports and configuring modems, refer to
Chapter 5, “Configuring an Asynchronous Port.”

Serial Port Settings for a Hardwired Connection

To establish a hardwired connection on a serial port, configure the port with the values
shown in Table 16-4.

Leave all other settings at their default values. After configuring the serial port, enter the
following commands to reset the port and save the configuration:

Command> reset s1
Command> save all

Table 16-4

Serial Port Values for a Hardwired Port

Setting

Command

Port type

set s1 network hardwired

Protocol

set s1 protocol ppp

MTU

set s1 mtu 1500

Speed 1

set s1 speed 1 115200

Modem control

set s1 cd on

Hardware flow control

set s1 rts/cts on

Software flow control

set s1 xon/xoff off

IP destination

set s1 destination 192.168.5.6

Netmask

set s1 netmask 255.255.255.0

RIP routing

set s1 rip off

Compression

set s1 compression on

Advertising