Configuring the portmaster 3 for channelized t1, Example channelized t1 configuration, Example channelized t1 configuration -11 – Lucent Technologies PortMaster User Manual

Page 179

Advertising
background image

Configuring the PortMaster 3

11-11

Using Channelized T1

Configuring the PortMaster 3 for Channelized T1

Follow these steps to configure the PortMaster 3 to use channelized T1 service:

1.

Set the line for inband signaling.

Command> set Line0 inband

2.

Set the signaling protocol and the line provisioning.

Command> set Line0 signaling wink|fxs inonly

3.

Set the framing format for the line.

Command> set Line0 framing esf|d4|crc4|fas

4.

Set the encoding method for the line.

Command> set Line0 encoding b8zs|ami

5.

Save the configuration changes and reboot.

Command> save all
Command> reboot

6.

Use the following command to display the line configuration.

Command> show

Line0

Example Channelized T1 Configuration

To configure the Line1 port on a PortMaster 3 for inband, channelized T1 for inbound
calls using E & M wink start, extended superframe format, and bipolar 8-zero
substitution, use the following commands:

Command> set line1 inband
Command> set line1 signaling wink inonly
Command> set line1 framing esf
Command> set line1 encoding b8zs
Command> save all
Command> reboot

Advertising