Lucent Technologies PortMaster User Manual

Page 97

Advertising
background image

Configuring an Asynchronous Port

5-21

Configuring a Port for a Dedicated Connection

To configure a port for a hardwired connection, follow this procedure:

1.

Set the port for network hardwired.

Command> set S0 network hardwired

2.

Set the protocol.

Command> set S0 protocol slip|ppp

3.

Set the maximum transmission unit (MTU) size.

Command> set S0 MTU MTU

4.

Set the destination IP address.

Command> set S0 destination Ipaddress

[Ipmask]

5.

Set the IPX network number if you are using IPX.

Command> set S0 ipxnet Ipxnetwork

6.

Enable RIP routing.

Command> set S0 rip on|off|broadcast|listen

7.

Set compression.

Command> set S0 compression on|off|stac|vj

8.

Set the PPP asynchronous map (if required).

Command> set S0 map Hex

9.

Set input and output filters (if using).

Command> set S0 ifilter [Filtername]
Command> set S0 ofilter [Filtername]

Omitting the Filtername removes any filter previously set on the port.

10. Save the configuration.

Command> save all

11. Reset the port.

Command> reset S0

Advertising