Configuration Steps for a Synchronous V.25bis Connection

14-8

PortMaster Configuration Guide

Configuring Global Settings

Configure the following global settings to the values shown in Table 14-6.

After you configure the global settings shown in Table 14-6, enter the following
command to save the configuration:

Command> save all

For more information about global settings, refer to Chapter 3, “Configuring Global
Settings
.”

Configuring Ethernet Interface Settings

Configure the Ethernet settings to the values shown in Table 14-7.

Table 14-6

Global Value

Setting

Command

IP gateway

set gateway 192.168.1.2

(This is the address of the next upstream router.)

Default routing

set default on

System name

set sysname miami

Table 14-7

Ethernet Values

Setting

Command

Protocol

set ether0 ipx enable

IP address

set ether0 address 192.168.1.1

Netmask

set ether0 netmask 255.255.255.0

IPX network

set ether0 ipxnet F2

IPX frame type

set ether0 ixpframe ethernet_802.2

Broadcast address

set ether0 broadcast high

RIP routing

set ether0 rip on