Modifying igmp interfaces – Lucent Technologies P550 User Manual

Page 143

Advertising
background image

Configuring IP Routing (Layer 3)

Cajun P550/P220 Switch Operation Guide

7-17

5. To enable MTRACE processing, from the MTRACE pull-down menu, select

Enable.

6. Click APPLY to save your changes, or CANCEL to restore previous settings.

Modifying IGMP Interfaces

To modify IGMP interfaces:

1. In the IGMP Configuration section of the Web Agent window, click Interfaces.

The IGMP Interfaces dialog box opens.

Note: If no IGMP interfaces are enabled for your existing IP interfaces, you must

first enable a multicast protocol before you can configure IGMP. Refer to
“Creating an IP Interface” earlier in this chapter for more information on
how to select a multicast protocol.

2. Use Table 7-8 to complete your configuration:

Table 7-8. IGMP Interface Parameters

Parameter

Allows you to...

Select

Select the interface to be modified.

Interface

Display the IP interface that is configured with IGMP.

IP Address

Identify an IP address associated with this interface. This
parameter is not configurable from the IGMP configuration
dialog box.

IP Address Mask

Identify a subnet mask associated with this interface. This
parameter is not configurable from the IGMP configuration
dialog box.

IGMP Version

Specify the IGMP Version (1.0 or 2.0) to associate with the
IGMP interface.

Maximum Groups

Specify the number of IGMP Groups that can be active on this
interface. The default value is 32.

Always be Group
Membership Querier

Version 1.0: Enable or disable this interface to be the
designated querier.

Version 2.0:

• Enable to force this interface to send queries.

• Disable to obey the designated querier election.

Only the designated router will query hosts on your network.
This is disabled by default.

Process Leave Packets

Enable to terminate group memberships quickly. (IGMP
Version 2.0 only). The default value is Enabled.

Query Request Interval in
(sec)

Configure the time period between queries. The default value
is 125 seconds.