Troubleshooting and repair – Lincoln Electric VRTEXTM 360 SVM200-A User Manual

Page 117

Advertising
background image

5 VOLT SUPPLY

FIGURE F.23 – 5 VOLT SUPPLY LOCATION

5VDC SUPPLY MODULE REMOVAL AND REPLACEMENT PROCEDURE

(continued)

REMOVAL PROCEDURE

1. Remove input power.
2. Perform the Monitor and Pedestal Removal

Procedure

.

3. Perform the Case Cover Removal Procedure.
4. Locate the 5VDC Supply Module. See Figure

F.23.

Note:

There are two supply modules located next

to each other. Make certain that you are

removing the correct module.

5. Using a small flathead screwdriver, remove

leads 102A (white), 103B (pink/red) and the

green ground lead from the bottom of the

Supply Module. See Figure F.24.

6. Label and remove the positive and negative

leads (81,81,50,50) from the top of the 5VDC

Module using the small flathead screwdriver.
See Figure F.24.

7. Push down on the release tab and lift up to

remove the 5VDC Supply Module from the DIN

rail.

TROUBLESHOOTING AND REPAIR