Troubleshooting and repair, Caution – Lincoln Electric VRTEXTM 360 SVM200-A User Manual

Page 62

Advertising
background image

POWER-UP PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3878.

CAUTION

(Continued)

If the correct input voltage is

being applied to the CPU and

the VRTEX

TM

360 does not

power-up the CPU may be

faulty.

TROUBLESHOOTING AND REPAIR

F-5

F-5

VRTEX

TM

360

The VRTEX

TM

360 does not

power up when the ON Switch is

pushed. The green indicator light

does come on but does NOT stay

on when the ON Switch is

released.

Make certain the correct input

voltage is being applied to the

VRTEX

TM

360. (115-230VAC

single phase).

With the ON Switch activated

5VDC should be present at the

Input Relay Coil. Terminal A1

(Red Lead) to Terminal A2

(Black Lead). See the wiring

diagram. If the green indicator

light is on the 5VDC should be

present at the relay coil.
Check for loose or faulty

connections between the Input

Relay, the Upper Terminal

Block and the ON Switch.

Check leads 101A and 103A.

See the wiring diagram.
If the 5VDC is being applied to

the Input Relay Coil and the

above mentioned connections

and leads are OK the Input

Relay Coil may be faulty.

Replace.
If the 5VDC is not present at

Terminals A1 to A2 check for

loose or faulty connections

between the Input Relay Coil

and the CPU USB port. See

the wiring diagram.
The CPU may be faulty.

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC