See figure f.26, Troubleshooting and repair – Lincoln Electric VRTEXTM 360 SVM200-A User Manual
Page 122
Advertising
+ + - -
+ + - -
5VDC/5A
5VDC/5A
DPP25-5
DPP25-5
N L
N L
DC ON
DC ON
DPP50-15
DPP50-15
+ + - -
+ + - -
15VDC/3.4A
15VDC/3.4A
N L
N L
DC ON
DC ON
Ground
(Green)
102B
(White)
103C
(Pink/Red)
71
71 72
72
FIGURE F.26 – 12/15 VOLT SUPPLY LEAD LOCATIONS
12/15VDC SUPPLY MODULE REMOVAL AND REPLACEMENT PROCEDURE
(continued)
REPLACEMENT PROCEDURE
1. Replace the 12/15VDC Supply Module.
2. Secure the new Supply Module to the DIN rail.
3. Connect all previously removed leads to their
proper locations on the Supply Module.
4. Perform the Case Cover Replacement
5. Perform the Monitor and Pedestal
TROUBLESHOOTING AND REPAIR
F-65