See figure, F.35, Troubleshooting and repair – Lincoln Electric VRTEXTM 360 SVM200-A User Manual

Page 135

Advertising
background image

FIGURE F.35 – SHORTCUT TO START-UP SIM SCREEN SHOT

INTERFACE MODULE DIGITAL (USB)

REMOVAL AND REPLACEMENT PROCEDURE (continued)

11. Click on the following in order:

• Start
• All Programs
• National Instruments
• Measurement and Automation
See Figure F.36

• Devices and Interfaces (click “+”)
• USB Devices
• Tools
• NI-Visa
• Visa Options
• Aliases
• Clear all Aliases
• OK
• Close out Screen
• YES (to save)

12. At this point, a basic computer screen desktop

will appear.

13. Click on the following in order:

• Start
• All Programs
• National Instruments
• Measurement and Automation
• Devices and Interfaces (click “+”)
• USB Devices (click “+”)
• USB 0……………….

14. In the box labeled “Visa Alias” on my system,

type these letters: LECSPI (in CAPS)

15. Save and close out screen.
16. Shut down the VRTEX

TM

360 via a normal CPU

shutdown. Click:

• Start
• Turn off computer
• Turn off

17. Remove input power after CPU has complete-

ly shut down.

18. Disconnect the USB keyboard and mouse.
19. Perform Case Cover Replacement

Procedure

.

20. Perform the Monitor and Pedestal

Replacement Procedure

.

21. See Retest After Repair.

TROUBLESHOOTING AND REPAIR

F-78

F-78

VRTEX

TM

360

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Advertising