Troubleshooting and repair, Caution – Lincoln Electric VRTEXTM 360 SVM200-A User Manual

Page 63

Advertising
background image

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3878.

CAUTION

TROUBLESHOOTING AND REPAIR

F-6

F-6

VRTEX

TM

360

POWER-UP PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

The VRTEX

TM

360 does not

power up when the ON Switch is

pushed. The green indicator light

does come on and stays on.

The green light indicates that

the CPU Computer Assembly is

receiving input power and

activating the green light via a

USB cable.

Verify that the green LEDs on

the 5VDC Power Supply and

the 12VDC Power Supply are

on. If they are not, then

perform the 5VDC Power
Supply Test

and the 12VDC

Power Supply Test.

Carefully check the input

voltage being applied to the

Monitor at leads #103 to #102.

It should be the same as the

input line voltage. (115-230VAC

single phase). See the wiring

diagram.
If the above checks are OK

then check for broken cables

and loose connections between

the CPU and the User

Interface, the 12VDC Supply

and the Relay PC Board and

the VGA Splitter, the 5VDC

supply and the FMD Control

Unit, and the Polhemus

Interface Module. See the

wiring diagram.