See figure f.2, Troubleshooting and repair, 5 vdc supply test procedure (continued) – Lincoln Electric VRTEXTM 360 SVM200-A User Manual

Page 74

Advertising
background image

+ + - -

5VDC/5A

DPP25-5

N L

DC ON

DPP50-15

DPP50-15

+ + - -

+ + - -

15VDC/3.4A

15VDC/3.4A

N L

N L

DC ON

DC ON

Ground
(Green)

102A
(White)

103B
(Pink/Red)

81

81 50

50

FIGURE F.2 – 5 VDC SUPPLY LEAD LOCATION

5 VDC SUPPLY TEST PROCEDURE (continued)

8. Using a volt/ohmmeter, check for the presence

of input power at leads 102A to 103B at the

supply terminals. See Figure F.2.

9. If the correct input voltage is not present in the

previous step, check for loose or faulty connec-

tions at the terminal blocks and associated

wiring. See wiring diagram.

10. Check for the presence of 5VDC at leads 50(-)

to 81(+). See wiring diagram. If 5 volts are

present, the 5 Volt Supply is functioning prop-

erly.

11. If 5VDC is not present, label and disconnect all

associated leads (50(-) to 81(+)) from the 5 Volt

Supply terminals.

12. Re-check for the presence of 5VDC at the

supply terminals.

13. If 5VDC is not present and the correct input

voltage is being applied, the 5 Volt Supply is

faulty. Replace. Perform the 5 VDC Supply
Removal and Replacement Procedure.

14. If 5VDC is present with all leads (50(-) to

81(+)) disconnected, there is a heavy load or

short circuit associated with leads 50(-) to

81(+) and the associated wiring. See wiring

diagram.

15. Replace all previously disconnected leads.
16. Perform the Case Cover Replacement

Procedure

.

17. Perform the Monitor and Pedestal

Replacement Procedure

.

TROUBLESHOOTING AND REPAIR