CAUTION

TROUBLESHOOTING AND REPAIR

F-10

F-10

VRTEX

TM

360

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3878.

FUNCTION PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

The VRTEX

TM

360 does not

function correctly in the SMAW

(stick) mode. But it functions

correctly in the VR GMAW mode.

Make certain the SMAW (stick)

electrode device is connected

properly.
Make sure the correct welding

procedures are set.

Check for loose or faulty

connections between the Motor

Control PC Board and the VR

SMAW Device. See the wiring

diagram.
Check for loose or faulty

connections between the Motor

Control PC Board and the

Relay PC Board. See the

wiring diagram.
Make sure the Motor Control

PC Board is receiving the

12VDC supply from the Relay

PC Board. Check at leads #72

to #73. If the 12VDC is not

present the Relay PC Board

may be faulty. See the wiring

diagram.
Check for loose or faulty

connections at the ribbon

cable, between the USB Digital

I/O Module and the terminal

block interface. Also check

between the terminal block

interface and the Relay Board.

See the wiring diagram.
Perform the Interface Digital
Module IO Test.

The VR SMAW device may be

faulty.