SOURCE

SYS

FIGURE F.47 – “SOURCE’ CABLE CONNECTED TO POLHEMUS MODULE

TABLE SWING ARM

REMOVAL AND REPLACEMENT PROCEDURE (continued)

REMOVAL PROCEDURE

1. Remove input power.
2. Perform the Monitor and Pedestal Removal

Procedure

.

3. Perform the Case Cover Removal Procedure.
4. Remove any coupons that are inserted into the

swing arm.

5. Disconnect the cable labeled “SOURCE” from

the polhemus module. See Figure F.47.

6. Remove the strain relief from the Table Swing

Arm cable at the rear of the machine. See
Figure F.48.

7. Remove any cable ties.
8. Carefully slide the Table Swing Arm off of the

top of the table mounting post.

9. Remove the plastic grommet from 1¾ “ access

hole in case back. See Figure F.48.

10. Remove the Table Swing Arm cable through

the case back via the 1¾” access hole.