Troubleshooting and repair, Warning – Lincoln Electric VRTEXTM 360 SVM200-A User Manual

Page 81

Advertising
background image

FMD CONTROLLER

HORIZONTAL
MOUNTING
SHELF

FMD (HELMET)

DOOR

FIGURE F.5 – FMD LOCATION

FACE MOUNTED DISPLAY (FMD) CONTROL UNIT TEST (continued)

TROUBLESHOOTING AND REPAIR

F-24

F-24

VRTEX

TM

360

TEST PROCEDURE

1. Disconnect the input power.
2. Perform the Monitor and Pedestal Removal

Procedure

.

3. Perform the Case Cover Removal Procedure.
4. Connect the input power.
5. Power up the machine.
6. Locate the FMD Control Unit. See Figure F.5.
7. Check to make sure the red LED on the Control

Unit is lit. See Figure F.6. If the red LED is not

lit, make sure the FMD power switch is in the

“ON” position. Not all units have an “ON”

switch.

8. Verify that the FMD Control Unit is receiving 5

VDC from the 5 volt power supply. If not, check

for loose or faulty connections between the 5

volt supply and the FMD control unit. See

wiring diagram.

ELECTRIC SHOCK can kill.

• Have a qualified individual

install and service this equip-

ment.

• Turn the input supply power OFF at the discon-

nect switch or fuse box before working on this

equipment.

• Do not touch electrically hot parts.

------------------------------------------------------------------

WARNING