5VDC/5A

DPP25-5

N L

DC ON

DPP50-15

DPP50-15

+ + - -

+ + - -

15VDC/3.4A

15VDC/3.4A

N L

N L

DC ON

DC ON

Ground
(Green)

102A
(White)

103B
(Pink/Red)

81

81 50

50

FIGURE F.24 – 5 VOLT SUPPLY LEAD LOCATIONS

5VDC SUPPLY MODULE REMOVAL AND REPLACEMENT PROCEDURE

(continued)

REPLACEMENT PROCEDURE

1. Replace the 5VDC Supply Module.
2. Secure the new Supply Module to the DIN rail.
3. Connect all previously removed leads to their

proper locations on the Supply Module.

4. Perform the Case Cover Replacement

Procedure

.

5. Perform the Monitor and Pedestal

Replacement Procedure

.

6. See Retest After Repair.