SENSOR 1

SENSOR 2

SOURCE

SYS

RS 232

USB

CONFIG

O
N

ON

OFF

DC

IN

FRONT

BACK

LED

FIGURE F.12 – POLHEMUS INTERFACE MODULE

POLHEMUS INTERFACE MODULE TEST PROCEDURE (continued)

7. Check to make sure the LED on the front of the

Polhemus Interface Module is lit. See Figure

F.12.

NOTE:

At initial power up, the LED will be red, then

a flashing red. When the machine is com-

pletely initialized, the LED will turn green.

8. Make sure the switch on the back of the

Polhemus Interface Module is in the “ON” posi-

tion.

9. Make sure all the dip switch settings are in the

down position. See Figure F.12.

10. If the LED is lit, check for loose or faulty con-

nections between the FMD control unit and the

following;

• Welding Stand
• CPU
• FMD Control Unit
• Relay PC Board

Note: See wiring diagram.

11. If the LED is not lit, check for the presence of

5VDC at the input terminal. See wiring dia-

gram.

12. If the LED is not lit and the 5VDC is present,

the Polhemus Interface Module may be faulty.

Perform the Polhemus Interface Module
Removal and Replacement Procedure.

12. Perform the Case Cover Replacement

Procedure

.

13. Perform the Monitor and Pedestal

Replacement Procedure

.

TROUBLESHOOTING AND REPAIR