If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3878.

CAUTION

TROUBLESHOOTING AND REPAIR

F-8

F-8

VRTEX

TM

360

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

FUNCTION PROBLEMS

The Display P.C. Board does not

function correctly. The VRTEX

TM

360 seems to work correctly.

Check for the presence of

5VDC at the Display Board

leads #201 to #202. See the

wiring diagram. If the 5VDC is

present and the Display does

not light the Display Board may

be faulty. Replace.
If the 5VDC is not present at

the Display Board check for the

presence of 5VDC at lead

#201 to #202 at the USB

Interface Module. See the

wiring diagram. If the 5VDC is

not present the USB Interface

Module may be faulty.
Perform the USB Interface
Module Test.

Some of the User Interface

Controls and/or Indicators do not

function.

Check the functionality of the

device(s) in question. The

switches and Joy Stick contacts

are momentary, normally open

devices. The indicators are

colored LEDs. See the wiring

diagram.
The Wire Feed Speed and

Output Controls are encoders

and are connected to the User

Interface Digital IO Module. See

the wiring diagram.
Make sure the devices in

question are not damaged and

are functional.

Check the continuity between

the non-functioning device(s)

and the User Interface Digital

IO Module. Check for loose or

faulty connections. See the

wiring diagram.
Check for loose or faulty

connections (ribbon cable)

between the User Interface

Digital I/O Module and the

terminal block interface.
Also, check the leads for loose

or faulty connections between

the terminal block interface and

the User Interface Controls and

Indicators. See wiring diagram.

All of the User Interface Controls

and Indicators do not function.

Make certain the correct input

voltage (115-230VAC single

phase) is being applied to the

VRTEX

TM

360 machine.

Perform the User Interface
Digital IO Module Test.

Check for loose or faulty

connections (USB cable)

between the CPU and the User

Interface Digital IO Module.

Check for loose or faulty

connections between the USB

Interface Module and the

Display Board. See the wiring

diagram.
Check for loose or faulty

connections at the USB cable

connecting the CPU to the USB

Interface Module.