FIGURE F.3 – 12/15 VDC SUPPLY LOCATION

12/15 VDC SUPPLY TEST PROCEDURE (continued)

TEST PROCEDURE

1. Disconnect the input power.
2. Perform the Monitor and Pedestal Removal

Procedure

.

3. Perform the Case Cover Removal Procedure.
4. Connect the input power.
5. Power up the machine.
6. Locate the 12/15 Volt Supply. See Figure F.3.
7. Check to make sure the green LED on back of

power supply is lit. See Figure F.4. If so, con-

tinue to step 10.

NOTE:

This indicates that the machine is receiv-

ing the correct input power. If the green

LED is not lit, continue to step 8.

TROUBLESHOOTING AND REPAIR

F-20

F-20

VRTEX

TM

360

12/15 VOLT SUPPLY

ELECTRIC SHOCK can kill.

• Have a qualified individual

install and service this equip-

ment.

• Turn the input supply power OFF at the discon-

nect switch or fuse box before working on this

equipment.

• Do not touch electrically hot parts.

------------------------------------------------------------------

WARNING