FIGURE F.4 – 12/15 VDC SUPPLY LEAD LOCATION

12/15 VDC SUPPLY TEST PROCEDURE (continued)

8. Using a volt/ohmmeter, check for the presence

of input power at leads 102B to 103C at the

supply terminals. See Figure F.4.

9. If the correct input voltage is not present in the

previous step, check for loose or faulty connec-

tions at the terminal blocks and associated

wiring. See wiring diagram.

10. Check for the presence of 12VDC at leads

72(-) to 71(+). See wiring diagram. If 12 volts

are present, the 12 Volt Supply is functioning

properly.

11. If 12VDC is not present, label and disconnect

all associated leads (72(-) to 71(+)) from the 12

Volt Supply terminals.

12. Re-check for the presence of 12VDC at the

supply terminals.

13. If 12VDC is not present and the correct input

voltage is being applied, the 12 Volt Supply is

faulty. Replace. Perform the 12/15 VDC
Supply

Removal

and

Replacement

Procedure.

14. If 12VDC is present with all leads (72(-) to

71(+)) disconnected, there is a heavy load or

short circuit associated with leads 72(-) to

71(+) and the associated wiring. See wiring

diagram.

15. Replace all previously disconnected leads.
16. Perform the Case Cover Replacement

Procedure

.

17. Perform the Monitor and Pedestal

Replacement Procedure

.

TROUBLESHOOTING AND REPAIR

F-21

F-21

VRTEX

TM

360

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Advertising