See figure f.6, Red led, Fro nt – Lincoln Electric VRTEXTM 360 SVM200-A User Manual

Page 82: Troubleshooting and repair

Advertising
background image

RED LED

FRO

NT

FIGURE F.6 – FMD CONTROL UNIT

FACE MOUNTED DISPLAY (FMD) CONTROL UNIT TEST (continued)

9. Check for loose or faulty connections between

the FMD control unit and the following;

• VGA Splitter

• Polhemus Control

• CPU

NOTE:

See wiring diagram.

10. If the FMD controller is receiving 5VDC and all

the proper connections are intact, the FMD

may be faulty. Replace. Perform the FMD
Control Unit Removal and Replacement
Procedure.

11. Perform the Case Cover Replacement

Procedure

.

12. Perform the Monitor and Pedestal

Replacement Procedure

.

TROUBLESHOOTING AND REPAIR

F-25