Mag-prover-calibration, 1 calibration items – Toshiba LF516 User Manual

Page 104

Advertising
background image


103

6 F 8 A 0 9 3 4

9. Mag-Prover-Calibration

9.1 Calibration Items

When you check or calibrate the converter or check the excitation current, you have to change the mode to
the calibration mode.

You can check or change the zero and span of the converter and the excitation current value as described
below.

However, calibration is already performed when shipped from the factory. Do not perform
change calibration unless it is specificity required.

Items

Function items

Display example

9.2.1

0 % flow rate calibration

CAL 0%

9.2.2

50 % flow rate calibration

CAL 50%

9.2.3

100 % flow rate calibration

CAL 100%

9.2.4

Checking the excitation current output

EXC DSPL

Advertising
This manual is related to the following products: