(2) Pipe Orientation

The detector may be installed in horizontal, vertical or sloping pipe runs as shown in
Figure 4.5. However, except for horizontal installation, fluid should flow from lower
to upper directions. See Figure 4.5.













Figure 4.5 Detector Piping Orientation


The electrodes should be positioned horizontally against the ground surface in any piping
installation. See Figure 4.6.







Figure 4.6 Installation position of the detector

Flow direction

(a) Horizontal pipe installation
(b) Vertical pipe installation
(c) Sloping pipe installation

Detector

Ground surface

(a)

(c)

(b)

Ground surface

Detector

Don’t rotate.