Toshiba LF516 User Manual

Page 149

Advertising
background image


148

6 F 8 A 0 9 3 4

Digital output function: Select one of the following:

Totalization pulse output:

Pulse rate

Max. 3kHz(3000pps)

DO1

Max. 100Hz( 100pps)

DO2 (option)

Pulse width

Can be set within a range of 0.3 to 500ms.
However, must be 40% or less of the full-scale cycle.
If the full scale 1000pps is exceeded,
automatically set to 40% of the full-scale cycle.

Multi-range switching output: In the case of fourfold range or forward/reverse

double range, you need to add digital output
optionally.

High and low alarm output

High-high and low-low alarm output

Empty alarm output

Preset counter output

Converter malfunction alarm output

Multiple range high and low limit alarm output (option)

Output display: Full-dot matrix 128 x 128-dot LCD (with back light)

Communication signal

Method (protocol): HART or PROFIBUS (option)

Load resistance:

240 to 750 (HART)

Load capacity:

0.25 F or less (HART)

Structure

IP67 and NEMA 4X

Housing

Aluminum alloy

Coating

Acrylic resin-baked coating, pearl-gray colored

Cable connection port

1/2-14NPT thread
Cable connections not provided.

Surge arresters

Surge arresters are installed in the power supply and current signal output circuit.

Advertising