Toshiba LF516 User Manual

Page 95

Advertising
background image


94

6 F 8 A 0 9 3 4

Operation when fixed output is set to ON

Current output

Output is the fixed current output value.

Pulse output

Output is the fixed pulse rate pulse signal.

Digital output other than
pulse output

Status in hold

Display

Display 2 screen: Used to indicate the fixed output
(Note)


Display example:

First line:

Pulse count (5 digits maximum), Unit: (PPS) fixed

Second line: Current output (4 digits including a decimal point), Unit: (mA) fixed

This fixed value output function does not work in the calibration mode.
When OFF is selected in the fixed output function, the setting for output is not needed.

●Changing the fixed output function

The following procedure shows how to set the fixed output to ON and set the fixed current
value/fixed pulse value. The fixed current value and fixed pulse value can be set
independently.

Switch operation

Display example

Description

Select "FIX SET" from the setting item
selection menu.

The current setting (OFF in this example)
appears.

Then push .

* Pushing returns you to the menu
screen.

The switches at the bottom change.
( are shown.)
At the same time, the cursor appears.
(The item indicated by the cursor is
highlighted.)

Then push .

You can continue to change the setting item.
Push to change the selection
items.

: Selected item is scrolled up.

: Selected item is scrolled down.

When the desired item is selected, push

to set the item temporarily.