Factory default standard value table

Parameter names

Default value(SI unit)

Default value(US unit)

Changed value

Excitation frequency

Value(*1)

Value(*1)

Flow direction

NORMAL

NORMAL

Display 1

m

3

/h gal/min

Display 2

m

3

B COUNT

B

Display digit setting
(for Display 1 and Display 2)

1/1000 1/1000

Custom coefficient

1.0

1.0

Custom unit

“ CUSTOM”
(Head of character string is
blank )

“ CUSTOM”
(Head of character string is
blank )

Range type

SINGLE SINGLE

Range 1

Value(*1)

Value(*1)

Ranges 2 to 4

0.00 m

3

/h 0.00

gal/min

Hysteresis

3.0 %

3.0 %

Damping constant

5.0 s

5.0 s

Rate-of-change limit

0.0 %

0.0 %

Control limit time

0.0 s

0.0 s

Low cutoff

1.0 %

1.0 %

Display low cutoff

LINEAR

LINEAR

Manual zero

0.0 %

0.0 %

4

−20mADC alarm output

4mA 4mA

Output low limit setting

4mA

4mA

Digital output 1

NO USE

NO USE

Digital output 2

NO USE

NO USE

DO1/DO2 active status

NormOPEN

NormOPEN

Digital input

NO USE

NO USE

DI detective level

H LEVEL

H LEVEL

Count rate

Value(*1)

Value(*1)

Pulse width setting mode

AUTO

AUTO

Pulse width

100 ms

5 ms

Preset count

00000000

00000000

Preset function

HOLD

HOLD

High alarm On/Off

OFF

OFF

High alarm value

0.0 %

0.0 %

Low alarm On/Off

OFF

OFF

Low alarm value

0.0 %

0.0 %

High-High alarm On/Off

OFF

OFF

High-High alarm value

0.0 %

0.0 %

Low-Low alarm On/Off

OFF

OFF

Low-Low alarm value

0.0 %

0.0 %

Self-diagnosis On/Off

ON

ON

Fixed value output

OFF

OFF

Fixed value current

4mA

4mA

Fixed value pulse

0 pps

0 pps

Password 000 000
LCD density adjustment

3

3

Switch position setting

BOTTOM

BOTTOM

*1 : Setting value by meter size please refer to the next list.