10 custom unit function – Toshiba LF516 User Manual

Page 129

Advertising
background image


128

6 F 8 A 0 9 3 4

10.10 Custom unit function

(1) Display of flow rate

The procedure to display flow rate by the custom unit is shown below.

Example : In the case of custom unit [dL(deciliter)/min].

Custom coefficient setting






Set the custom coefficient in accordance with 8.2.7 “Custom Coefficient

Setting”. Set the conversion coefficient from m

3

/min

unit to the custom

coefficient. In the case of dL/min, set 10000 that is the conversion coefficient
of dL from m

3

.

Custom unit setting






Set the custom unit in accordance with 8.2.8 “Custom Unit Setting”. Set the

character string of unit to the custom unit. In the case of this example, set ‘d’
‘L’ ‘/’ ‘m’ ‘i’ ‘n’. The rest of 1 character is blank space because the maximum
character number of the custom unit is 7.

Display

setting

Set the display item to CUSTOM in accordance with 8.2.6 “Display Setting”.

Measurement value

confirmation






Return to the measurement mode and confirm the display value. Identification

character “ ” showing the custom unit is displayed at the head of custom unit
in the measurement mode.

Advertising