2 procedure for communications with hht – Toshiba LF516 User Manual

Page 133

Advertising
background image


132

6 F 8 A 0 9 3 4




















Figure 11.2 Connections to the Converter Unit

11.2 Procedure for Communications with HHT

This section describes the HHT basic operation procedure for communications between the flowmeter
and HHT. For details, refer to the HHT instruction manual.
* The following procedure makes a commercially available PDA (OS: Windows Mobile) serve as a

HHT.

Procedure Operation

Prepare a hand-held terminal (1)

Install the AF900 application software to a commercially available PDA (OS:
Windows Mobile) main unit. Then insert the serial interface card supplied with
AF900 to the card slot of the PDA.

Prepare a hand-held terminal (2)

Connect the HART interface cable and serial interface card supplied with
AF900 to each other.

Connect

Connect the alligator clip at the head of the HART interface cable to the current
output line of the converter via a load resistor.

Start

Turn on the power supply of the PDA to start the AF900 application software.

Preliminary communication

Execute [sensor communication]. The model of the connected sensor product
is automatically identified and the converter menu screen appears.

Check/change data

Press the relevant parameter button and check/change data.

Exit the communication

When all operations are complete, press the [Exist Application] in the top
screen to turn off the power supply of the PDA.

HHT connection cable and clips

Converter terminal block

HHT