Af-600 fp high power operating instructions, 3 e-## digital in /outs – GE Industrial Solutions AF-600 FP Fan and Pump Drive (460V_575V 150HP and above) User Manual

Page 125

Advertising
background image

Par

. No.

#

Pa

ram

et

er d

escri

ption

De

fa

ul

t va

lu

e

4-set-u

p

Ch

an

ge

du

rin

g

ope

ra-

tion

Co

nv

er

-

sion inde

x

Typ

e

E-0#

E-00

D

igi

tal

I/

O

Mo

de

[0] PNP - Active at 24V

All set-ups

FA

LSE

-

U

int8

E-01

Ter

m

in

al

1

8 D

igi

ta

l In

pu

t

[8

] S

ta

rt

All se

t-u

ps

TR

U

E

-

Ui

nt

8

E-02

Te

rm

in

al 19

Dig

ital

Inp

ut

[0] N

o

operati

on

All set-u

ps

TR

U

E

-

U

in

t8

E-03

Ter

m

in

al

2

7 D

igi

ta

l In

pu

t

nu

ll

All se

t-u

ps

TR

U

E

-

Ui

nt

8

E-04

Te

rm

in

al 29

Dig

ital

Inp

ut

[1

4]

J

og

Al

l set-up

s

TRUE

-

U

int8

E-05

Ter

m

in

al

3

2 D

igi

ta

l In

pu

t

[0] No

operation

All se

t-u

ps

TR

U

E

-

Ui

nt

8

E-06

Te

rm

in

al 33

Dig

ital

Inp

ut

[0] N

o

operati

on

All set-u

ps

TR

U

E

-

U

in

t8

E-1#

E-10

Acc

el

Ti

me 2

Ex

pr

essio

nLimit

All set-ups

TR

U

E

-2

U

int32

E-11

De

ce

l Ti

me

2

Ex

pr

essio

nLimit

All se

t-u

ps

TR

U

E

-2

Uin

t32

E-2#

E-20

Terminal 27

Dig

ital Outp

ut

[0] No

operation

All se

t-u

ps

TR

U

E

-

Ui

nt

8

E-21

Te

rm

in

al 29

Dig

ital

Outp

ut

[0]

No

o

per

at

io

n

Al

l set-up

s

TRUE

-

U

int8

E-24

Func

tio

n Re

la

y

nu

ll

All se

t-u

ps

TR

U

E

-

Ui

nt

8

E-26

On

Del

ay, Rela

y

0.01 s

All set-u

ps

TR

U

E

-2

U

in

t16

E-27

Of

f Del

ay,

Re

la

y

0.01 s

All se

t-u

ps

TR

U

E

-2

Uin

t16

E-5#

E-51

Te

rm

in

al 27

Mode

[0] Input

All se

t-u

ps

TR

U

E

-

Ui

nt

8

E-52

Te

rm

in

al 29

Mode

[0] Input

All set-ups

TR

U

E

-

U

int8

E-53

Te

rm

in

al X

30/2 Di

gita

l I

nput

[0] No

operation

All se

t-u

ps

TR

U

E

-

Ui

nt

8

E-54

Te

rm

in

al X

30/3 Di

gita

l In

put

[0] N

o

operati

on

All set-u

ps

TR

U

E

-

U

in

t8

E-55

Te

rm

in

al X

30/4 Di

gita

l I

nput

[0] No

operation

All se

t-u

ps

TR

U

E

-

Ui

nt

8

E-56

Te

rm

X30/6 Di

gi

Ou

t (OPC

G

PIO)

[0]

No

o

per

at

io

n

Al

l set-up

s

TRUE

-

U

int8

E-57

Te

rm

X30/7 Di

gi

Ou

t (OPC

G

PIO)

[0] No

operation

All se

t-u

ps

TR

U

E

-

Ui

nt

8

E-6#

E-60

Te

rm

. 2

9 Lo

w Fr

eq

ue

nc

y

100 Hz

All se

t-u

ps

TR

U

E

0

Uin

t32

E-

61

Ter

m

. 29

Hi

gh

Fr

eq

ue

ncy

100 Hz

All set-u

ps

TR

U

E

0

Ui

nt32

E-62

Te

rm

. 2

9 Lo

w Ref

./F

eed

b.

V

alu

e

0.000

N/A

All se

t-u

ps

TR

U

E

-3

In

t3

2

E-63

Te

rm

. 2

9 High

Ref./Feedb.

Va

lu

e

100.00

0 N

/A

All set-u

ps

TR

U

E

-3

In

t32

E-64

Pu

lse

Fi

lte

r Ti

me

Co

ns

ta

nt

#2

9

10

0 ms

All se

t-u

ps

FAL

SE

-3

Uin

t16

E-65

Te

rm

. 3

3 Lo

w Fr

eq

ue

nc

y

100 Hz

All set-u

ps

TR

U

E

0

Ui

nt32

E-66

Ter

m

. 33

Hi

gh

Fr

eq

ue

ncy

100 Hz

All se

t-u

ps

TR

U

E

0

Uin

t32

E-

67

Te

rm

. 3

3 Lo

w Ref

./F

eed

b.

V

alu

e

0.000

N/A

All set-u

ps

TR

U

E

-3

In

t32

E-68

Te

rm

. 3

3 High

Re

f./F

ee

db.

Val

ue

100.00

0 N

/A

All se

t-u

ps

TR

U

E

-3

In

t3

2

E-

69

Pu

lse

Fi

lte

r Ti

me

Co

ns

ta

nt

#3

3

100

m

s

Al

l set-up

s

FAL

SE

-3

Uin

t1

6

7.2.

3

E-## Digital In

/Outs

AF-600 FP High Power Operating Instructions

123

7