Mains Supply 3 x 525- 600 VAC
P110
P132
P160
P200
Typical Shaft output at 550 V
[kW]
110
132
160
200
Typical Shaft output at 575 V
[HP]
150
200
250
300
Unit Size IP21
41
41
42
42
Unit Size IP54
41
41
42
42
Unit Size IP00
43
43
44
44
Output current
Continuous
(at 550 V) [A]
162
201
253
303
Intermittent (60 sec over-
load)
(at 550 V) [A]
178
221
278
333
Continuous
(at 575 V) [A]
155
192
242
290
Intermittent (60 sec over-
load)
(at 575 V) [A]
171
211
266
319
Continuous KVA
(at 550 V) [KVA]
154
191
241
289
Continuous KVA
(at 575 V) [KVA]
154
191
241
289
Max. input current
Continuous
(at 550 V ) [A]
158
198
245
299
Continuous
(at 575 V) [A]
151
189
234
286
Max. cable size, mains mo-
tor, load share and brake
[mm
2
(AWG)]
2 x 70 (2 x 2/0)
2 x 70 (2 x 2/0)
2 x 185 (2 x 350 mcm) 2 x 185 (2 x 350 mcm)
Max. external pre-fuses [A]
1
315
350
350
400
Estimated power loss
at rated max. load [W]
4)
3114
3612
4292
5156
Weight,
Unit Size IP21, IP 54 [kg]
96
104
125
136
Weight,
Unit Size IP00 [kg]
82
91
112
123
Efficiency
4)
0.98
Output frequency
0 - 600 Hz
Heatsink overtemp. trip
85 °C
90 °C
110 °C
110 °C
Power card ambient trip
60 °C
AF-600 FP High Power Operating Instructions
156