8 General Specifications

Mains supply (L1, L2, L3):

Supply voltage

380-480 V ±10%

Supply voltage

525-600 V ±10%

Supply frequency

50/60 Hz

Max. imbalance temporary between mains phases

3.0 % of rated supply voltage

True Power Factor (λ)

≥ 0.9 nominal at rated load

Displacement Power Factor (cosφ) near unity

(> 0.98)

Switching on input supply L1, L2, L3 (power-ups)

maximum once/2 min.

Environment according to EN60664-1

overvoltage category III / pollution degree 2

The unit is suitable for use on a circuit capable of delivering not more than 100.000 RMS symmetrical Amperes, 480/600 V maximum.

Motor output (U, V, W):

Output voltage

0 - 100% of supply voltage

Output frequency

0 - 800* Hz

Switching on output

Unlimited

Accel/Decel Times

1 - 3600 sec.

* Voltage and power dependent

Torque characteristics:

Starting torque (Constant torque)

maximum 110% for 1 min.

*

Starting torque

maximum 135% up to 0.5 sec.

*

Overload torque (Constant torque)

maximum 110% for 1 min.

*

*Percentage relates to AF-600 FP Drive's nominal torque.

Cable lengths and cross sections:

Max. motor cable length, screened/armoured

AF-600 FP Drive: 150 m

Max. motor cable length, unscreened/unarmoured

AF-600 FP Drive: 300 m

Max. cross section to motor, mains, load sharing and brake *

Maximum cross section to control terminals, rigid wire

1.5 mm

2

/16 AWG (2 x 0.75 mm

2

)

Maximum cross section to control terminals, flexible cable

1 mm

2

/18 AWG

Maximum cross section to control terminals, cable with enclosed core

0.5 mm

2

/20 AWG

Minimum cross section to control terminals

0.25 mm

2

* See Mains Supply tables for more information!

Digital inputs:

Programmable digital inputs

4 (6)

Terminal number

18, 19, 27

1)

, 29, 32, 33,

Logic

PNP or NPN

Voltage level

0 - 24 V DC

Voltage level, logic'0' PNP

< 5 V DC

Voltage level, logic'1' PNP

> 10 V DC

Voltage level, logic '0' NPN

> 19 V DC

Voltage level, logic '1' NPN

< 14 V DC

Maximum voltage on input

28 V DC

Input resistance, R

i

approx. 4 k

All digital inputs are galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
1) Terminals 27 and 29 can also be programmed as output.