Af-600 fp high power operating instructions – GE Industrial Solutions AF-600 FP Fan and Pump Drive (460V_575V 150HP and above) User Manual

Page 155

Advertising
background image

Mains Supply 3 x 380 - 480 VAC

P110

P132

P160

P200

P250

Typical Shaft output at
400 V [kW]

110

132

160

200

250

Typical Shaft output at
460 V [HP]

150

200

250

300

350

Unit Size IP21

41

41

42

42

42

Unit Size IP54

41

41

42

42

42

Unit Size IP00

43

43

44

44

44

Output current
Continuous
(at 400 V) [A]

212

260

315

395

480

Intermittent (60 sec
overload)
(at 400 V) [A]

233

286

347

435

528

Continuous
(at 460 V) [A]

190

240

302

361

443

Intermittent (60 sec
overload)
(at 460 V) [A]

209

264

332

397

487

Continuous KVA
(at 400 V) [KVA]

147

180

218

274

333

Continuous KVA
(at 460 V) [KVA]

151

191

241

288

353

Max. input current

Continuous
(at 400 V ) [A]

204

251

304

381

463

Continuous
(at 460 V) [A]

183

231

291

348

427

Max. cable size, mains
motor, brake and load
share [mm

2

(AWG

2)

)]

2 x 70

(2 x 2/0)

2 x 70

(2 x 2/0)

2 x 185

(2 x 350 mcm)

2 x 185

(2 x 350 mcm)

2 x 185

(2 x 350 mcm)

Max. external pre-fuses
[A]

1

300

350

400

500

600

Estimated power loss
at rated max. load [W]

4)

3234

3782

4213

5119

5893

Weight,
Unit Size IP21, IP 54 [kg]

96

104

125

136

151

Weight,
Unit Size IP00 [kg]

82

91

112

123

138

Efficiency

4)

0.98

Output frequency

0 - 800 Hz

Heatsink overtemp. trip

85 °C

90 °C

105 °C

105 °C

115 °C

Power card ambient trip

60 °C