Af-600 fp high power operating instructions, 15 dr-## data readouts – GE Industrial Solutions AF-600 FP Fan and Pump Drive (460V_575V 150HP and above) User Manual

Page 140

Advertising
background image

Par

. No.

#

Pa

ram

et

er d

escri

ption

De

fa

ul

t va

lu

e

4-set-u

p

Ch

an

ge

du

rin

g

ope

ra-

tion

Co

nv

er

-

sion inde

x

Typ

e

DR

-0#

DR

-00

Co

nt

rol

Word

0 N

/A

All se

t-u

ps

FA

LS

E

0

V2

DR

-01

Re

fe

re

nc

e [

U

ni

t]

0.

00

0 Re

fe

re

nc

eF

ee

db

ac

kU

nit

All se

t-u

ps

FAL

SE

-3

In

t3

2

DR

-0

2

Ref

ere

nce

[%

]

0.0 %

All set-u

ps

FA

LSE

-1

In

t16

DR

-03

Sta

tus Wo

rd

0 N

/A

All se

t-u

ps

FAL

SE

0

V2

DR

-05

M

ai

n A

ctua

l Va

lu

e [%]

0.00 %

All set-u

ps

FA

LSE

-2

N

2

DR

-09

Cu

st

om Re

adou

t

0.

00

Cu

st

om

Re

ad

ou

tU

nit

All se

t-u

ps

FAL

SE

-2

In

t3

2

DR

-1#

DR

-10

Po

wer [kW]

0.

00

k

W

All se

t-u

ps

FAL

SE

1

In

t3

2

DR

-11

Po

w

er [h

p]

0.00 hp

All

set-u

ps

FA

LSE

-2

In

t32

DR

-12

Moto

r R

ated V

olta

ge

0.

0 V

All se

t-u

ps

FAL

SE

-1

Uin

t16

DR

-13

Fre

qu

en

cy

0.0 Hz

All set-u

ps

FA

LSE

-1

Ui

nt16

DR

-14

Moto

r C

urre

nt

0.00 A

All se

t-u

ps

FAL

SE

-2

In

t3

2

DR

-15

Fre

qu

en

cy

[%

]

0.00 %

All set-u

ps

FA

LSE

-2

N

2

DR

-16

To

rq

ue

[N

m]

0.0 N

m

All se

t-u

ps

FAL

SE

-1

In

t3

2

DR

-17

Spe

ed [RPM]

0 RPM

All set-ups

FA

LSE

67

In

t32

DR

-18

Motor Th

ermal

0 %

All se

t-u

ps

FAL

SE

0

Ui

nt

8

DR

-2#

DR

-22

To

rq

ue

[%]

0 %

All se

t-u

ps

FAL

SE

0

In

t1

6

DR

-3#

DR

-30

D

C L

in

k Vol

tage

0 V

All se

t-u

ps

FAL

SE

0

Uin

t16

DR

-32

Brake E

nerg

y

/s

0.000 kW

All set-u

ps

FA

LSE

0

U

in

t32

DR

-33

Br

ak

e E

nerg

y /

2 m

in

0.000 kW

All se

t-u

ps

FAL

SE

0

Uin

t32

DR

-34

H

ea

tsi

nk T

emp

.

0 °C

All

set-u

ps

FA

LSE

100

U

in

t8

DR

-35

Dr

iv

e T

her

ma

l

0 %

All se

t-u

ps

FAL

SE

0

Ui

nt

8

DR

-36

D

rive

Nom

inal

C

urre

nt

Ex

pr

essio

nLimit

All set-ups

FA

LSE

-2

Uint32

DR

-37

Dr

iv

e M

ax.

Cu

rr

en

t

Ex

pr

essio

nLimit

All se

t-u

ps

FAL

SE

-2

Uin

t32

DR

-38

Logi

c Con

tro

lle

r Sta

te

0 N/

A

All set-ups

FA

LSE

0

U

int8

DR

-39

Co

nt

ro

l C

ard

T

em

p.

0 °C

All se

t-u

ps

FAL

SE

100

Ui

nt

8

DR

-4#

DR

-40

Tr

end

ing

Bu

ff

er

Fu

ll

[0

] No

All se

t-u

ps

TR

U

E

-

Ui

nt

8

DR

-5#

DR

-50

Ex

te

rn

al Re

fe

ren

ce

0.

0 N

/A

All se

t-u

ps

FAL

SE

-1

In

t1

6

DR

-52

Fe

edb

ac

k [Un

it]

0.000 Pr

ocessCt

rlUn

it

All set-u

ps

FA

LSE

-3

In

t32

DR

-53

Di

gi

P

ot

R

ef

er

ence

0.

00

N/A

All se

t-u

ps

FAL

SE

-2

In

t1

6

DR

-54

Fe

edb

ac

k 1

[Un

it]

0.000 Pr

ocessCt

rlUn

it

All set-u

ps

FA

LSE

-3

In

t32

DR

-55

Fee

dba

ck

2

[Uni

t]

0.000 Pr

ocessCt

rlUn

it

All se

t-u

ps

FAL

SE

-3

In

t3

2

DR

-56

Fe

edb

ac

k 3

[Un

it]

0.000 Pr

ocessCt

rlUn

it

All set-u

ps

FA

LSE

-3

In

t32

DR

-58

PI

D Ou

tpu

t [%]

0.0 %

All se

t-u

ps

TR

U

E

-1

In

t1

6

DR

-6#

DR

-60

D

igi

tal

In

pu

t

0 N

/A

All se

t-u

ps

FAL

SE

0

Uin

t16

D

R-61

Ter

mi

na

l 53 S

w

itch

Se

tt

in

g

[0

] C

ur

ren

t

All s

et

-u

ps

FA

LS

E

-

U

in

t8

DR

-62

An

al

og

In

pu

t 5

3

0.000

N/A

All se

t-u

ps

FAL

SE

-3

In

t3

2

D

R-63

Ter

mi

na

l 54 S

w

itch

Se

tt

in

g

[0

] C

ur

ren

t

All s

et

-u

ps

FA

LS

E

-

U

in

t8

DR

-64

An

al

og

In

pu

t 5

4

0.000

N/A

All se

t-u

ps

FAL

SE

-3

In

t3

2

DR

-65

Ana

log

Ou

tpu

t 42 [m

A]

0.000

N/A

All set-u

ps

FA

LSE

-3

In

t16

DR

-66

D

igital O

utput

[b

in]

0 N

/A

All se

t-u

ps

FAL

SE

0

In

t1

6

DR

-67

Freq. Inp

ut

#29 [Hz]

0 N/

A

Al

l set-up

s

FAL

SE

0

Int3

2

DR

-68

Fr

eq

. In

pu

t #33 [Hz]

0 N

/A

All se

t-u

ps

FAL

SE

0

In

t3

2

DR

-69

Pu

lse Outp

ut

#27 [Hz]

0 N/

A

Al

l set-up

s

FAL

SE

0

Int3

2

7.2.

15

DR-## Data Readouts

AF-600 FP High Power Operating Instructions

138

7

Advertising