Af-600 fp high power operating instructions, 22 pc-## pump controller – GE Industrial Solutions AF-600 FP Fan and Pump Drive (460V_575V 150HP and above) User Manual
Page 148
Par
. No.
#
Pa
ram
et
er d
escri
ption
De
fa
ul
t va
lu
e
4-set-u
p
Ch
an
ge
du
rin
g
ope
ra-
tion
Co
nv
er
-
sion inde
x
Typ
e
PC
-0
#
PC
-0
0
Pu
m
p C
ont
roll
er
[0] Disabled
2 set-ups
FA
LSE
-
U
int8
PC
-0
2
Motor S
tart
[0] D
irect on L
ine
2 set-ups
FAL
SE
-
Ui
nt
8
PC
-0
4
Pu
m
p C
ycli
ng
[0] Disabled
All
set-ups
TR
U
E
-
U
int8
PC
-0
5
Fi
xed Le
ad Pum
p
[1] Y
es
2 set-ups
FAL
SE
-
Ui
nt
8
PC
-0
6
N
um
be
r of
Pu
m
ps
2 N/
A
2 set-ups
FA
LSE
0
U
int8
PC
-1
#
PC
-2
#
PC
-2
0
St
agi
ng
Ban
dwi
dth
10 %
All se
t-u
ps
TR
U
E
0
Ui
nt
8
PC
-2
1
O
ve
rr
ide
Ban
dwi
dth
10
0 %
All set-u
ps
TR
U
E
0
U
in
t8
PC
-2
2
Fi
xed S
pee
d Ba
ndwi
dth
ca
sco
_st
agin
g_ba
nd
w
idth
(P
2520)
All se
t-u
ps
TR
U
E
0
Ui
nt
8
PC
-2
3
SBW
Sta
gin
g De
lay
15 s
All set-u
ps
TR
U
E
0
Ui
nt16
PC
-2
4
SB
W De
stagi
ng De
la
y
15 s
All se
t-u
ps
TR
U
E
0
Uin
t16
PC
-2
5
O
BW T
im
e
10 s
All set-u
ps
TR
U
E
0
Ui
nt16
PC
-2
6
D
estage
At No
-F
low
[0] Disabled
All se
t-u
ps
TR
U
E
-
Ui
nt
8
PC
-2
7
Stage
F
un
cti
on
[1] E
na
ble
d
All se
t-u
ps
TR
U
E
-
Ui
nt
8
PC
-2
8
St
age
F
un
cti
on T
ime
15 s
All se
t-u
ps
TR
U
E
0
Uin
t16
PC
-2
9
D
es
ta
ge
Function
[1] E
na
ble
d
All se
t-u
ps
TR
U
E
-
Ui
nt
8
PC
-3
#
PC
-3
0
De
st
ag
e Fun
ct
io
n Ti
me
15 s
All se
t-u
ps
TR
U
E
0
U
int16
PC
-4
#
PC
-4
0
De
ce
l R
amp
D
el
ay
10.0 s
All set-ups
TR
U
E
-1
U
int16
PC
-4
1
Ac
ce
l R
amp
D
ela
y
2.0 s
All se
t-u
ps
TR
U
E
-1
Uin
t16
PC
-4
2
Stagi
ng
T
hresh
ol
d
Ex
pr
essio
nLimit
All set-ups
TR
U
E
0
U
int8
PC
-4
3
D
estaging Thresho
ld
Ex
pr
essio
nLimit
All se
t-u
ps
TR
U
E
0
Ui
nt
8
PC
-4
4
Stagi
ng
Spe
ed
[RPM]
0 RPM
All set-ups
TR
U
E
67
U
int16
PC
-4
5
St
agi
ng
S
pee
d
[Hz]
0.0 Hz
All se
t-u
ps
TR
U
E
-1
Uin
t16
PC
-4
6
D
es
ta
gin
g S
pee
d [
RPM
]
0 RPM
All set-ups
TR
U
E
67
U
int16
PC
-4
7
D
esta
gin
g Spe
ed [Hz
]
0.0 Hz
All se
t-u
ps
TR
U
E
-1
Uin
t16
PC
-5
#
PC
-5
0
Le
ad
P
um
p Al
ter
na
tio
n
[0
] Of
f
All se
t-u
ps
TR
U
E
-
Ui
nt
8
PC
-5
1
Al
ter
na
tio
n Even
t
[0] E
xte
rn
al
All set-ups
TR
U
E
-
U
int8
PC
-5
2
Al
ternation Time
Inte
rv
al
24 h
All se
t-u
ps
TR
U
E
74
Uin
t16
PC
-5
3
Alte
rn
ati
on Ti
me
r Val
ue
0 N/
A
All set-ups
TR
U
E
0
Vi
sStr[7]
PC
-5
4
Al
te
rn
at
io
n Pred
ef
in
ed T
im
e
Ex
pr
essio
nLimit
All se
t-u
ps
TR
U
E
0
Ti
me
Of
Da
y-
WoDa
te
PC
-5
5
Altern
ate if
Lo
ad < 50%
[1] E
na
ble
d
All se
t-u
ps
TR
U
E
-
Ui
nt
8
PC
-5
6
St
agi
ng
Mode at Al
ter
na
tion
[0
] Sl
ow
All se
t-u
ps
TR
U
E
-
Ui
nt
8
PC
-5
8
Run
N
ext P
um
p De
lay
0.1 s
All set-u
ps
TR
U
E
-1
U
in
t16
PC
-5
9
Ru
n o
n Li
ne
D
el
ay
0.5 s
All se
t-u
ps
TR
U
E
-1
Uin
t16
PC
-8
#
PC
-8
0
Pu
m
p S
tatu
s
0 N
/A
All se
t-u
ps
TR
U
E
0
VisStr[25]
PC
-8
1
Pu
m
p S
tatu
s
0 N
/A
All set-u
ps
TR
U
E
0
VisStr[25]
PC
-8
2
Le
ad
Pu
mp
0 N
/A
All se
t-u
ps
TR
U
E
0
Ui
nt
8
PC
-8
3
Rel
ay St
at
us
0 N/
A
All set-ups
TR
U
E
0
Vi
sStr[4]
PC
-8
4
Pu
mp
ON
Ti
me
0 h
All se
t-u
ps
TR
U
E
74
Uin
t32
PC
-8
5
Rel
ay ON
Ti
me
0 h
All set-ups
TR
U
E
74
U
int32
PC
-8
6
Re
se
t R
el
ay
Co
un
te
rs
[0] Do not r
eset
All se
t-u
ps
TR
U
E
-
Ui
nt
8
PC
-9
#
PC
-9
0
Pu
m
p I
nt
erl
ock
[0
] Of
f
All se
t-u
ps
TR
U
E
-
Ui
nt
8
PC
-9
1
M
anua
l Al
ter
na
tio
n
0 N/
A
Al
l set-up
s
TRUE
0
U
int8
7.2.
22
PC-## Pump
Controller
AF-600 FP High Power Operating Instructions
146
7