5.2.6 Rated Power

Unit Size

41

42

43

44

IP

21/54

21/54

00

00

NEMA

Type 1/ Type 12

Type 1/ Type 12

Chassis

Chassis

Light duty rated power
- 160% overload tor-
que

150 - 200 HP at 460 V

(380 - 480 V)

150 - 200 HP at 575 V

(525-600 V)

250 - 350 HP at 460 V

(380 - 480 V)

250 - 400 HP at 575 V

(525-600 V)

150 - 200 HP at 460 V

(380 - 480 V)

150 - 200 HP at 575 V

(525-600 V)

250 - 350 HP at 460 V

(380 - 480 V)

250 - 400 HP at 575 V

(525-600 V)

Unit Size

51

52

61/63

62/64

IP

21/54

00

21/54

21/54

NEMA

Type 1/ Type 12

Chassis

Type 1/ Type 12

Type 1/ Type 12

Light duty rated pow-
er - 160% overload
torque

350 - 600 HP at 460 V

(380 - 480 V)

450 - 650 HP at 575 V

(525-600 V)

350 - 600 HP at 460 V

(380 - 480 V)

450 - 650 HP at 575 V

(525-600 V)

650 - 1000 HP at 460 V

(380 - 480 V)

750 - 1050 HP at 575 V

(525-600 V)

1200 - 1350 HP at 460 V

(380 - 480 V)

1150 - 1350 HP at 575 V

(525-600 V)

NB!
The unit sizes 6X have four different sizes, 61, 62, 63 and 64 The 61 and 62 consist of an inverter cabinet on the right and rectifier cabinet on the left. The 63 and
64 have an additional options cabinet left of the rectifier cabinet. The 63 is an 61 with an additional options cabinet. The 64 is an 62 with an additional options