Af-600 fp high power operating instructions – GE Industrial Solutions AF-600 FP Fan and Pump Drive (460V_575V 150HP and above) User Manual

Page 161

Advertising
background image

Mains Supply 3 x 525- 600 VAC

P560

P670

P750

P850

P1M0

Typical Shaft output at
550 V [kW]

560

670

750

850

1000

Typical Shaft output at
575 V [HP]

750

950

1050

1150

1350

Unit Size IP21, 54 with-
out/ with options cabi-
net

61/ 63

61/ 63

61/ 63

62/ 64

62/ 64

Output current
Continuous
(at 550 V) [A]

763

889

988

1108

1317

Intermittent (60 sec
overload)
(at 550 V) [A]

839

978

1087

1219

1449

Continuous
(at 575 V) [A]

730

850

945

1060

1260

Intermittent (60 sec
overload)
(at 575 V) [A]

803

935

1040

1166

1386

Continuous KVA
(at 550 V) [KVA]

727

847

941

1056

1255

Continuous KVA
(at 575 V) [KVA]

727

847

941

1056

1255

Max. input current

Continuous
(at 550 V ) [A]

743

866

962

1079

1282

Continuous
(at 575 V) [A]

711

828

920

1032

1227

Max. cable size,motor
[mm

2

(AWG

2)

)]

8x150

(8x300 mcm)

12x150

(12x300 mcm)

Max. cable size,mains
[mm

2

(AWG

2)

)]

8x240

(8x500 mcm)

Max. cable size, load-
sharing [mm

2

(AWG

2)

)]

4x120

(4x250 mcm)

Max. cable size, brake
[mm

2

(AWG

2)

)

4x185

(4x350 mcm)

6x185

(6x350 mcm)

Max. external pre-fuses
[A]

1

1600

2000

Estimated power loss
at rated max. load [W]

4)

Weight,
Unit Size IP21, IP 54 [kg]

1004/ 1299

1004/ 1299

1004/ 1299

1246/ 1541

1246/ 1541

Weight, Rectifier Module
[kg]

102

102

102

136

136

Weight, Inverter Module
[kg]

102

102

136

102

102

Efficiency

4)

0.98

Output frequency

0-500 Hz

Heatsink overtemp. trip

85 °C

Power card ambient trip

68 °C

1) For type of fuse see section Fuses.

2) American Wire Gauge.

3) Measured using 5 m screened motor cables at rated load and rated frequency.

4) The typical power loss is at nominal load conditions and expected to be within +/-15% (tolerence relates to variety in voltage and cable conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line). Motors with lower efficiency will also add to the power loss in the frequency converter
and opposite.
If the switching frequency is increased compared to the default setting, the power losses may rise significantly.
Keypad and typical control card power consumptions are included. Further options and customer load may add up to 30W to the losses. (Though typical
only 4W extra for a fully loaded control card, or options for slot A or slot B, each).
Although measurements are made with state of the art equipment, some measurement inaccuracy must be allowed for (+/-5%).

AF-600 FP High Power Operating Instructions

159