Af-600 fp high power operating instructions, 6 tips and tricks – GE Industrial Solutions AF-600 FP Fan and Pump Drive (460V_575V 150HP and above) User Manual

Page 79

Advertising
background image

4.

Open the appropriate file

5.

Choose “Write to drive”

All parameter settings are now transferred to the frequency converter.

A separate manual forDrives Control Tool DCT 10 Software is available: from GE or the web: www.geelectrical.com/drives.

The Drives Control Tool DCT 10 Software Modules
The following modules are included in the software package:

DCT 10 Software
Setting parameters
Copy to and from frequency converters
Documentation and print out of parameter settings incl. diagrams

Ext. User Interface
Preventive Maintenance Schedule
Clock settings
Timed Action Programming
Logic Controller Set-up

Ordering number:
Please contact GE or visit: www.geelectrical.com/drives

6.1.6 Tips and tricks

*

For the majority of HVAC applications the Quick Menu, Quick Set-up and Macros Set-up provides the simplest and quickest access to
all the typical parameters required.

*

Whenever possible, performing an auto tuning, will ensure best shaft performance

*

Contrast of the display can be adjusted by pressing [Status] and [

] for darker display or by pressing [Status] and [

] for brighter

dispaly

*

Under [Quick Menu] and [Parameter Data Check] all parameters that have been changed from factory settings are displayed

*

Press and hold [Main Menu] key for 3 seconds for access to any parameter

*

For service purposes it is recommended to copy all parameters to the Keypad, see par. K-50 Keypad Copy for further information

Table 6.1: Tips and tricks

6.1.7 Quick Transfer of Parameter Settings when using keypad

Once the set-up of a frequency converter is complete, it is recommended to store (backup) the parameter settings in the keypad or on a PC via DCT 10 software.

NB!
Stop the motor before performing any of these operations.

Data storage in Keypad:

1.

Go to par. K-50 Keypad Copy

2.

Press the [OK] key

3.

Select “All to Keypad”

4.

Press the [OK] key

All parameter settings are now stored in the keypad indicated by the progress bar. When 100% is reached, press [OK].

The keypad can now be connected to another frequency converter and the parameter settings copied to this frequency converter.

AF-600 FP High Power Operating Instructions

78

6