The L_LCB_LogicControlBasic library

L_LCB_TablePositioning

126

Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

xProfileStart

BOOL

Start/stop positioning
TRUE

Start/restart positioning process

• The profile has to be selected at the wProfileNumberSet input.

Note: During an active positioning process, another profile can

already be defined via wProfileNumberSet which will be executed

after the restart (renewed state change "0" to "1").

• A positioning process previously aborted will be continued.

FALSE

• Abort the active positioning process.

xProfileRestart

BOOL

FALSETRUE Update of the profile data of a currently active profile considering

the distance already covered.

xProfileReset

BOOL

FALSETRUE A profile previously aborted cannot be continued anymore

• When xProfileStart = TRUE: Restart of a profile.

wProfileNumberSet

WORD

Profile number of the profile to be executed of the profile data management

• 9400 (1 .... 75)

• 8400 (3 ... 15),

xEnableSpeedOverride

BOOL

TRUE: Switch on speed override

rSpeedOverrideSet

REAL

Value for speed override in [%]

• 0 ... 199.99 %

xEnablePositionOverride

BOOL

NOTE: The second receive PDO (RPDO) has to be activated in the »PLC Designer« for

the CAN bus system for a position override to work (tab PDO Mapping). This setting

is not required for the EtherCAT bus system.
TRUE

Switch on position override

rPositionSet

REAL

Position selection in [Units]

Identifier/data type

Information/possible settings

xError

BOOL

"Error" status signal

FALSE Conversion carried out without errors

TRUE Error during the conversion

eError

L_LCB_Error

Error number, error code

xCommunicationOk

BOOL

Status of bus communication

FALSE No bus communication active

TRUE Bus communication available

xInternalControlActive

BOOL

TRUE: The output signals that the xEnableInternalControl input and the Internal

Control button of the visualisation have been activated. Hence, all selections are

made via visualisation.

xDriveError

BOOL

Status signal "Error active in the controller - acknowledgement required"

xDriveWarning

BOOL

TRUE: Controller is in "Warning" device state

xDriveReady

BOOL

Status signal "Controller is ready for operation"

xDriveEnabled

BOOL

TRUE: Controller has been enabled

xDriveQSPActive

BOOL

Status signal "Quick stop through application active"

xSpeedEqZero

BOOL

Status signal "Standstill reached" (observe speed value in code 19!)

Identifier/data type

Information/possible settings